{"id":279,"date":"2024-10-04T06:58:21","date_gmt":"2024-10-04T06:58:21","guid":{"rendered":"http:\/\/www.saeesolution.com\/?post_type=product&#038;p=279"},"modified":"2024-10-04T06:58:21","modified_gmt":"2024-10-04T06:58:21","slug":"tr-photo-t-w-triga-triga","status":"publish","type":"product","link":"https:\/\/www.saeesolution.com\/index.php\/product\/tr-photo-t-w-triga-triga\/","title":{"rendered":"TR-PHOTO-T-W &#8211; TRIGA (TRIGA)"},"content":{"rendered":"<p style=\"font-weight: 400;\">Multi-Criteria Fire\/CO Detector<\/p>\n<p style=\"font-weight: 400;\">\n<p style=\"font-weight: 400;\"><b><strong>GENERAL DESCRIPTION<\/strong><\/b><\/p>\n<p style=\"font-weight: 400;\">\nTR-PHOTO-T-W &#8211; TRIGA \/TR-FIRE-CO-W and TR-FIRE-CO-IV are plug-in addressable<a href=\"https:\/\/www.trigaglobal.com\/product-category\/addressable-detectors-bases\/\">\u00a0devices<\/a>\u00a0that provide both \ufb01re and carbon monoxide\u00a0<a href=\"https:\/\/en.wikipedia.org\/wiki\/Carbon_monoxide_detector\">(CO) detection<\/a>. The detector combines four separate sensing elements to sense multiple components of a \ufb01re: smoke, CO, light\/\ufb02ame, and heat. This approach enables enhanced sensitivity to real \ufb01re with heightened immunity to nuisance particulates. For CO, the detector\u2019s electrochemical sensing cell creates a separate signal for life safety CO detection.<\/p>\n<p style=\"font-weight: 400;\">Multiple sensors and communication can greatly reduce nuisance alarms compared to single sensing methods. Sophisticated algorithms maximize the advantages of all four sensor types creating our best detection strategy offering heightened immunity to nuisance particulate and enhanced sensitivity to real \ufb01re.<\/p>\n<p style=\"font-weight: 400;\">\n<ul>\n<li style=\"font-weight: 400;\">Photoelectric sensors detect airborne particles associated with smoke.<\/li>\n<li style=\"font-weight: 400;\">Thermal sensors detect heat and rate-of-rise (135\u00b0F \ufb01xed temperature threshold).<\/li>\n<li style=\"font-weight: 400;\">Infrared sensors discern light patterns in the environment as an additional data point for alarm determination.<\/li>\n<\/ul>\n<p style=\"font-weight: 400;\">\n<p style=\"font-weight: 400;\">This ability to reject certain nuisance alarm triggers, such as theater smoke, supports the use of the \ufb01re\/CO detector in applications where moderate to heavy nuisance conditions exist that might cause single sensing detectors to false alarm.<\/p>\n<p style=\"font-weight: 400;\">\n<p style=\"font-weight: 400;\">Meets UL 268 7th edition and UL 521 listing requirements for \ufb01re detection and UL 2075 standard for system-connected life safety carbon monoxide detection.<\/p>\n<p style=\"font-weight: 400;\">\n<p style=\"font-weight: 400;\">Released through the incomplete burning of various fuels, CO is a colorless, odorless and deadly gas that is virtually impossible to detect with the human senses. Because the<br \/>\npotential exists for dangerous levels of CO to accumulate in almost any building, legislation mandating the use of CO detection in commercial spaces continues to grow.<\/p>\n<p style=\"font-weight: 400;\">TR-B200S series intelligent sounder bases are recommended for use with TR-FIRE-CO-W and TR-FIRE-CO-IV. These bases can generate either a Temp 3 pattern for \ufb01re or a Temp 4 pattern for CO alarm indication. The TR-B200S series bases recognize the Triga synchronization protocol for use as a component of the general evacuation signal \u2013 along with other Triga Audible\/Visible devices \u2013 when connected to a power supply or Fire Alarm Control Panel (FACP) output capable of generating the System Sensor synchronization pulses.<\/p>\n","protected":false},"excerpt":{"rendered":"<ul>\n<li style=\"font-weight: 400;\">Detects all four major elements of a \ufb01re<\/li>\n<li style=\"font-weight: 400;\">Separate CO detection signal<\/li>\n<li style=\"font-weight: 400;\">Separate audible signal for \ufb01re or CO alarm when used with a TR-B200S-series base<\/li>\n<li style=\"font-weight: 400;\">Highest nuisance alarm immunity<\/li>\n<li style=\"font-weight: 400;\">Automatic drift compensation for smoke and CO sensors<\/li>\n<li style=\"font-weight: 400;\">RealTest\u00ae CO testing capability<\/li>\n<li style=\"font-weight: 400;\">New modern pro\ufb01le with expanded color options<\/li>\n<li style=\"font-weight: 400;\">Uses only one address on the SLC loop<\/li>\n<li style=\"font-weight: 400;\">UL 268 7th edition, UL 521 and UL 2075 listed<\/li>\n<li style=\"font-weight: 400;\">10-year CO cell with end-of-life warning<\/li>\n<\/ul>\n<p style=\"font-weight: 400;\">\n<p style=\"font-weight: 400;\"><b><strong>PHYSICAL\/OPERATING<\/strong><\/b><br \/>\nDimensions: Height: 2.7\u2033 (69 mm) installed in TR-B200S series sounder base<br \/>\nDiameter: 6.875\u2033 (175 mm) installed in TR-B200S series sounder base<br \/>\nWeight: 3.4 oz. (95 g)<br \/>\nOperating Humidity Range: 15% to 90% Relative Humidity, Non-condensing<br \/>\nOperating Temperature Range: 32\u00b0F to 100\u00b0F (0\u00b0C to 38\u00b0C)<br \/>\nAir Velocity: 0 to 4000 ft.\/min. (0 to 1219.2 m\/min.)<\/p>\n<p style=\"font-weight: 400;\">\n<p style=\"font-weight: 400;\"><b><strong>ELECTRICAL SPECIFICATIONS<\/strong><\/b><br \/>\nOperating Voltage Range: 15 to 32 VDC<br \/>\nOperating Current @ 24 VDC: 200 uA (one communication every 5 seconds with green LED blink on communication) Maximum Alarm Current: 2 mA @ 24 VDC (one communication every 5 seconds with red LED solid on)<br \/>\nMaximum Current: 4.5 mA @ 24 VDC (one communication every 5 seconds with amber LED solid on)<br \/>\nIsolator Load Rating: 0.0063<\/p>\n<p style=\"font-weight: 400;\">\n<p style=\"font-weight: 400;\"><b><strong>CO MONITORING UL STANDARD REFERENCE<\/strong><\/b><br \/>\nAlarm thresholds (in parts per million) are as follows for:<\/p>\n<p style=\"font-weight: 400;\">70 \u00b1 5ppm: Detector response time 60 \u2013 240 min.<br \/>\n150 \u00b1 5ppm: Detector response time 10 \u2013 50 min.<br \/>\n400 \u00b1 10ppm: Detector response time 4 \u2013 15 min.<\/p>\n<p style=\"font-weight: 400;\">\n<p style=\"font-weight: 400;\"><b><strong>STANDARDS<\/strong><\/b><br \/>\nPer UL standard 2075, the IDP-FIRE-CO-W and IDP-FIRE-CO-IV have been tested to the sensitivity limits de\ufb01ned in UL Standard 2034.<br \/>\nUL Standard: UL 268 7th Edition<\/p>\n<p style=\"font-weight: 400;\">\n<p style=\"font-weight: 400;\"><b><strong>AGENCY LISTINGS AND APPROVALS<\/strong><\/b><br \/>\nThe listings and approvals below apply to the TR-FIRE-CO-W and TR-FIRE-CO-IV. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult the factory for the latest listing status.<br \/>\nUL Listed<br \/>\nFM approved<\/p>\n<p style=\"font-weight: 400;\">\n<p style=\"font-weight: 400;\"><b><strong>ORDERING INFORMATION<\/strong><\/b><br \/>\nTR-FIRE-CO-W: Advanced multi-criteria \ufb01re\/CO detector, bright white color.<br \/>\nTR-FIRE-CO-IV: Advanced multi-criteria \ufb01re\/CO detector, ivory color<\/p>\n<p style=\"font-weight: 400;\">\n<p style=\"font-weight: 400;\"><b><strong>BASES<\/strong><\/b><br \/>\nTR-B501-WHITE: 4\u2033 Mounting base, white<br \/>\nTR-B501-IV: 4\u2033 Mounting base, ivory<br \/>\nTR-B501-BL: 4\u2033 Mounting base, black<br \/>\nTR-B300-6: 6\u2033 Flanged mounting base, white TR-B300-6-IV: 6\u2033 Flanged mounting base, ivory TR-B200S-WH: Intelligent addressable sounder base, white<br \/>\nTR-B200S-IV: Intelligent addressable sounder base, ivory TR-B200S-LF-WH: Intelligent addressable sounder base, low-frequency, white<br \/>\nTR-B200S-LF-IV: Intelligent addressable sounder base, low-frequency, ivory<br \/>\nTR-B224BI-WH: Isolator base, white<br \/>\nTR-B224BI-IV: Isolator base, ivory<br \/>\nTR-B224RB-WH: Relay base, white<br \/>\nTR-B224RB-IV: Relay base, ivory<\/p>\n<p style=\"font-weight: 400;\">\n<p style=\"font-weight: 400;\"><b><strong>ACCESSORIES<\/strong><\/b><br \/>\nTR-RA100Z: Remote LED annunciator<\/p>\n","protected":false},"featured_media":280,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[31],"product_tag":[],"class_list":{"0":"post-279","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-multi-detector","7":"product-grid-view","9":"first","10":"instock","11":"shipping-taxable","12":"product-type-simple"},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/www.saeesolution.com\/index.php\/wp-json\/wp\/v2\/product\/279","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.saeesolution.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.saeesolution.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.saeesolution.com\/index.php\/wp-json\/wp\/v2\/comments?post=279"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.saeesolution.com\/index.php\/wp-json\/wp\/v2\/media\/280"}],"wp:attachment":[{"href":"https:\/\/www.saeesolution.com\/index.php\/wp-json\/wp\/v2\/media?parent=279"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.saeesolution.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=279"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.saeesolution.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=279"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}